Test Case taDOM2+/13-taDOM2+-0-PA

taDOM2+ Lock Requests of executed Operation getValue(contextTextNode) returns Node

The getValue operation executed on a text context node returns the string node CS appended to the text node that represents the actual node value.

Behavior specified with base operations:

  • readCO
  • readCS
Read Set = CO CS , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
  • LockRequest[node=CS,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]

taDOM2+ Lock Requests of checked Operation getNode(DeweyID) executed on node PA

The getNode operation returns the context node CO addressed by the passed deweyID.

Bahavior specified with base operations:

  • readCO

Read and write sets for execution on PA:

Read Set = PA , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on PA
  • LockRequest[node=CN,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on PA

Operations must be compatible

CheckExisting LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on PA
Requested lock IR on AC compatible to existing lock IR.
Requested lock NR on PA compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CN,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on PA
Requested lock IR on AC compatible to existing lock IR.
Requested lock IR on PA compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=CS,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on PA
Requested lock IR on AC compatible to existing lock IR.
Requested lock NR on PA compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=CS,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CN,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on PA
Requested lock IR on AC compatible to existing lock IR.
Requested lock IR on PA compatible to existing lock IR.
Compatible
Test Case Ok