Test Case taDOM3+/13-taDOM3+-6-PS

taDOM3+ Lock Requests of executed Operation getValue(contextTextNode) returns Node

The getValue operation executed on a text context node returns the string node CS appended to the text node that represents the actual node value.

Behavior specified with base operations:

  • readCO
  • readCS
Read Set = CO CS , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
  • LockRequest[node=CS,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]

taDOM3+ Lock Requests of checked Operation getFirstChild(contextElementNode) executed on node PS

The getFirstChild operation returns the first child FC of the context node CO.

Bahavior specified with base operations:

  • readCO
  • useCOFCE
  • readFC
  • useFCPSE

Read and write sets for execution on PS:

Read Set = PS , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:ER,LCE:-] on PS
  • LockRequest[node=FC,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] on PS

Operations must be compatible

CheckExisting LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:ER,LCE:-] on PS
Requested lock IR on AC compatible to existing lock IR.
Requested lock IR on PA compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=FC,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] on PS
Requested lock IR on AC compatible to existing lock IR.
Requested lock IR on PA compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=CS,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:ER,LCE:-] on PS
Requested lock IR on AC compatible to existing lock IR.
Requested lock IR on PA compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=CS,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=FC,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] on PS
Requested lock IR on AC compatible to existing lock IR.
Requested lock IR on PA compatible to existing lock IR.
Compatible
Test Case Ok