UniKL Logo

Lehrgebiet Informationssysteme

FB Informatik

FB Informatik
 
LG IS
AG DBIS
AG HIS
Jobs / Tasks
Courses
Publications
Contact
Misc
Impressum
(C) AG DBIS
 

Test Case taDOM3+/17-taDOM3+-10-DC

taDOM3+ Lock Requests of executed Operation setValue(contextElementNode, valueString) returns Node

The setValue operation executed on the context element node CO returns the modified context element itself. In taDOM2(+) the CX lock on PA must be requested additionally in order to prevent an execution of the getChildNodes() method on the parent node.

Behavior specified with base operations:

  • writeCO
Read Set = , Write Set = CO
  • LockRequest[node=CO,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-]

taDOM3+ Lock Requests of checked Operation getChildNodes(contextElementNode) executed on node DC

The getChildNodes operation returns a node list with all child nodes of the context node CO.

Bahavior specified with base operations:

  • readCO
  • readFC
  • readCH
  • readLC
  • useCOFCE
  • useCOLCE
  • useFCPSE
  • useFCNSE
  • useCHPSE
  • useCHNSE
  • useLCPSE
  • useLCNSE

Read and write sets for execution on DC:

Read Set = DC DCFCE DCLCE DCPSE DCNSE , Write Set =
  • LockRequest[node=CO,lock:LR,PSE:-,NSE:-,FCE:-,LCE:-] on DC

Operations must be compatible

CheckExisting LockRequest[node=CO,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:LR,PSE:-,NSE:-,FCE:-,LCE:-] on DC
Requested lock IR on AC compatible to existing lock IX.
Requested lock IR on PA compatible to existing lock CX.
Requested lock IR on CO compatible to existing lock NX.
Compatible
Test Case Ok