Test Case taDOM3+/18-taDOM3+-30-PAtaDOM3+ Lock Requests of executed Operation setValue(contextTextNode, valueString) returns NodeThe setValue operation executed on the context text node CO returns the modified context string node CS which contains the actual node value.
Behavior specified with base operations:Read Set = CO , Write Set = CS - LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
- LockRequest[node=CS,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-]
taDOM3+ Lock Requests of checked Operation insertAfter(contextNode, siblingType, siblingValue) executed on node PAThe insertAfter operation is executed on the context element node CO and inserts a new next sibling node after the context node CO. There does not exist a next sibling, so the context element node was the last child of the parent node PA and the inserted new sibling node (the new last child of PA) is returned.
Bahavior specified with base operations:- readCO
- modifyCONSE
- modifyPALCE
Read and write sets for execution on PA:Read Set = PA , Write Set = - LockRequest[node=CO,lock:NR,PSE:-,NSE:EX,FCE:-,LCE:-] on PA
- LockRequest[node=PA,lock:CX,PSE:-,NSE:-,FCE:-,LCE:EX] on PA
Operations must be compatibleCheck | Existing LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] with Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:EX,FCE:-,LCE:-] on PA | Requested lock IR on AC compatible to existing lock IR. Requested lock NR on PA compatible to existing lock IR.
| Compatible | Check | Existing LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] with Requested LockRequest[node=PA,lock:CX,PSE:-,NSE:-,FCE:-,LCE:EX] on PA | Requested lock CX on AC compatible to existing lock IR.
| Compatible | Check | Existing LockRequest[node=CS,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-] with Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:EX,FCE:-,LCE:-] on PA | Requested lock IR on AC compatible to existing lock IX. Requested lock NR on PA compatible to existing lock IX.
| Compatible | Check | Existing LockRequest[node=CS,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-] with Requested LockRequest[node=PA,lock:CX,PSE:-,NSE:-,FCE:-,LCE:EX] on PA | Requested lock CX on AC compatible to existing lock IX.
| Compatible | Test Case Ok |
|