Test Case taDOM3+/2-taDOM3+-15-AC

taDOM3+ Lock Requests of executed Operation getPrevSibling(contextNode) returns Node

The getPrevSibling operation returns the previous sibling node PS of the context node CO.

Behavior specified with base operations:

  • readCO
  • useCOPSE
  • readPS
  • usePSNSE
Read Set = PS CO PSNSE COPSE , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]
  • LockRequest[node=PS,lock:NR,PSE:-,NSE:ER,FCE:-,LCE:-]

taDOM3+ Lock Requests of checked Operation getAttribute(contextElementNode, ctxAttrNameString) executed on node AC

The getAttribute operation executed on the context element node CO returns the context attribute node CA with the passed attribute name.

Bahavior specified with base operations:

  • readCO
  • readCA

Read and write sets for execution on AC:

Read Set = AC , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on AC
  • LockRequest[node=CA,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on AC

Operations must be compatible

CheckExisting LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on AC
Requested lock NR on AC compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CA,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on AC
Requested lock IR on AC compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=PS,lock:NR,PSE:-,NSE:ER,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on AC
Requested lock NR on AC compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=PS,lock:NR,PSE:-,NSE:ER,FCE:-,LCE:-]
with
Requested LockRequest[node=CA,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on AC
Requested lock IR on AC compatible to existing lock IR.
Compatible
Test Case Ok