Test Case taDOM3+/2-taDOM3+-19-CAtaDOM3+ Lock Requests of executed Operation getPrevSibling(contextNode) returns NodeThe getPrevSibling operation returns the previous sibling node PS of the context node CO.
Behavior specified with base operations:- readCO
- useCOPSE
- readPS
- usePSNSE
Read Set = PS CO PSNSE COPSE , Write Set = - LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]
- LockRequest[node=PS,lock:NR,PSE:-,NSE:ER,FCE:-,LCE:-]
taDOM3+ Lock Requests of checked Operation setValue(contextAttrNode, valueString) executed on node CAThe setValue operation executed on the context attribute node CA returns the modified attribute string node AS which contains the actual node value.
Bahavior specified with base operations:Read and write sets for execution on CA:Read Set = CA , Write Set = AS - LockRequest[node=CA,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on CA
- LockRequest[node=AS,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-] on CA
Operations must be compatibleCheck | Existing LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] with Requested LockRequest[node=CA,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on CA | Requested lock IR on AC compatible to existing lock IR. Requested lock IR on PA compatible to existing lock IR. Requested lock IR on CO compatible to existing lock NR.
| Compatible | Check | Existing LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] with Requested LockRequest[node=AS,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-] on CA | Requested lock IX on AC compatible to existing lock IR. Requested lock IX on PA compatible to existing lock IR. Requested lock IX on CO compatible to existing lock NR.
| Compatible | Check | Existing LockRequest[node=PS,lock:NR,PSE:-,NSE:ER,FCE:-,LCE:-] with Requested LockRequest[node=CA,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on CA | Requested lock IR on AC compatible to existing lock IR. Requested lock IR on PA compatible to existing lock IR.
| Compatible | Check | Existing LockRequest[node=PS,lock:NR,PSE:-,NSE:ER,FCE:-,LCE:-] with Requested LockRequest[node=AS,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-] on CA | Requested lock IX on AC compatible to existing lock IR. Requested lock IX on PA compatible to existing lock IR.
| Compatible | Test Case Ok |
|