UniKL Logo

Lehrgebiet Informationssysteme

FB Informatik

FB Informatik
 
LG IS
AG DBIS
AG HIS
Jobs / Tasks
Courses
Publications
Contact
Misc
Impressum
(C) AG DBIS
 

Test Case taDOM3+/22-taDOM3+-3-AC

taDOM3+ Lock Requests of executed Operation renameAttribute(contextElementNode, ctxAttrOldNameString, ctxAttrNewNameString) returns Node

The renameAttribute operation is executed on the context element node CO and renames the context attribute CA with the passed old name to the passed new name. In taDOM2(+) the CX lock on AR must be requested additionally in order to prevent an execution of the getAttributes() method on the context node. The operation returns the rename attribute node CA.

Behavior specified with base operations:

  • readCO
  • writeCA
Read Set = CO , Write Set = CA
  • LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
  • LockRequest[node=CA,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-]

taDOM3+ Lock Requests of checked Operation getPrevSibling(contextNode) executed on node AC

The getPrevSibling operation returns null because the context node CO is the first child of parent node PA and no previous sibling node PS exists.

Bahavior specified with base operations:

  • readCO
  • useCOPSE
  • usePAFCE

Read and write sets for execution on AC:

Read Set = AC , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] on AC
  • LockRequest[node=PA,lock:-,PSE:-,NSE:-,FCE:ER,LCE:-] on AC

Operations must be compatible

CheckExisting LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] on AC
Requested lock NR on AC compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=PA,lock:-,PSE:-,NSE:-,FCE:ER,LCE:-] on AC
Compatible
CheckExisting LockRequest[node=CA,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] on AC
Requested lock NR on AC compatible to existing lock IX.
Compatible
CheckExisting LockRequest[node=CA,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=PA,lock:-,PSE:-,NSE:-,FCE:ER,LCE:-] on AC
Compatible
Test Case Ok