UniKL Logo

Lehrgebiet Informationssysteme

FB Informatik

FB Informatik
 
LG IS
AG DBIS
AG HIS
Jobs / Tasks
Courses
Publications
Contact
Misc
Impressum
(C) AG DBIS
 

Test Case taDOM3+/24-taDOM3+-22-PS

taDOM3+ Lock Requests of executed Operation appendChild(contextElementNode, childType, childValue) returns Node

The appendChild operation is executed on the context element node CO and appends a new child. The context element node CO has still no child nodes before this operation. The CX resp. NRCX lock on the context node is caused by the SX lock on the new child.The new appended child node (the now only child) is returned.

Behavior specified with base operations:

  • readCO
  • modifyCOFCE
  • modifyCOLCE
Read Set = CO , Write Set = COFCE COLCE
  • LockRequest[node=CO,lock:NRCX,PSE:-,NSE:-,FCE:EX,LCE:EX]

taDOM3+ Lock Requests of checked Operation renameAttribute(contextElementNode, ctxAttrOldNameString, ctxAttrNewNameString) executed on node PS

The renameAttribute operation is executed on the context element node CO and renames the context attribute CA with the passed old name to the passed new name. In taDOM2(+) the CX lock on AR must be requested additionally in order to prevent an execution of the getAttributes() method on the context node. The operation returns the rename attribute node CA.

Bahavior specified with base operations:

  • readCO
  • writeCA

Read and write sets for execution on PS:

Read Set = PS , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on PS
  • LockRequest[node=CA,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-] on PS

Operations must be compatible

CheckExisting LockRequest[node=CO,lock:NRCX,PSE:-,NSE:-,FCE:EX,LCE:EX]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:-,LCE:-] on PS
Requested lock IR on AC compatible to existing lock IX.
Requested lock IR on PA compatible to existing lock IX.
Compatible
CheckExisting LockRequest[node=CO,lock:NRCX,PSE:-,NSE:-,FCE:EX,LCE:EX]
with
Requested LockRequest[node=CA,lock:NX,PSE:-,NSE:-,FCE:-,LCE:-] on PS
Requested lock IX on AC compatible to existing lock IX.
Requested lock IX on PA compatible to existing lock IX.
Compatible
Test Case Ok