Test Case taDOM3+/29-taDOM3+-24-CHtaDOM3+ Lock Requests of executed Operation insertAfter(contextNode, siblingType, siblingValue) returns NodeThe insertAfter operation is executed on the context element node CO and inserts a new next sibling node after the context node CO. There already exists a next sibling and the inserted new sibling node is returned.
Behavior specified with base operations:- readCO
- modifyCONSE
- modifyNSPSE
Read Set = CO , Write Set = CONSE NSPSE - LockRequest[node=CO,lock:NR,PSE:-,NSE:EX,FCE:-,LCE:-]
- LockRequest[node=NS,lock:-,PSE:EX,NSE:-,FCE:-,LCE:-]
- LockRequest[node=PA,lock:CX,PSE:-,NSE:-,FCE:-,LCE:-]
taDOM3+ Lock Requests of checked Operation appendChild(contextElementNode, childType, childValue) executed on node CHThe appendChild operation is executed on the context element node CO and appends a new child. The context element node CO has still no child nodes before this operation. The CX resp. NRCX lock on the context node is caused by the SX lock on the new child.The new appended child node (the now only child) is returned.
Bahavior specified with base operations:- readCO
- modifyCOFCE
- modifyCOLCE
Read and write sets for execution on CH:Read Set = CH , Write Set = CHFCE CHLCE - LockRequest[node=CO,lock:NRCX,PSE:-,NSE:-,FCE:EX,LCE:EX] on CH
Operations must be compatibleCheck | Existing LockRequest[node=CO,lock:NR,PSE:-,NSE:EX,FCE:-,LCE:-] with Requested LockRequest[node=CO,lock:NRCX,PSE:-,NSE:-,FCE:EX,LCE:EX] on CH | Requested lock IX on AC compatible to existing lock IR. Requested lock IX on PA compatible to existing lock IR. Requested lock IX on CO compatible to existing lock NR.
| Compatible | Check | Existing LockRequest[node=NS,lock:-,PSE:EX,NSE:-,FCE:-,LCE:-] with Requested LockRequest[node=CO,lock:NRCX,PSE:-,NSE:-,FCE:EX,LCE:EX] on CH | | Compatible | Check | Existing LockRequest[node=PA,lock:CX,PSE:-,NSE:-,FCE:-,LCE:-] with Requested LockRequest[node=CO,lock:NRCX,PSE:-,NSE:-,FCE:EX,LCE:EX] on CH | Requested lock IX on AC compatible to existing lock IX. Requested lock IX on PA compatible to existing lock CX.
| Compatible | Test Case Ok |
|