UniKL Logo

Lehrgebiet Informationssysteme

FB Informatik

FB Informatik
 
LG IS
AG DBIS
AG HIS
Jobs / Tasks
Courses
Publications
Contact
Misc
Impressum
(C) AG DBIS
 

Test Case taDOM3+/4-taDOM3+-29-CO

taDOM3+ Lock Requests of executed Operation getNextSibling(contextNode) returns Node

The getNextSibling operation returns the next sibling node NS of the context node CO.

Behavior specified with base operations:

  • readCO
  • useCONSE
  • readNS
  • useNSPSE
Read Set = CO NS CONSE NSPSE , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:-,NSE:ER,FCE:-,LCE:-]
  • LockRequest[node=NS,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]

taDOM3+ Lock Requests of checked Operation insertAfter(contextNode, siblingType, siblingValue) executed on node CO

The insertAfter operation is executed on the context element node CO and inserts a new next sibling node after the context node CO. There already exists a next sibling and the inserted new sibling node is returned.

Bahavior specified with base operations:

  • readCO
  • modifyCONSE
  • modifyNSPSE

Read and write sets for execution on CO:

Read Set = CO , Write Set = CONSE NSPSE
  • LockRequest[node=CO,lock:NR,PSE:-,NSE:EX,FCE:-,LCE:-] on CO
  • LockRequest[node=NS,lock:-,PSE:EX,NSE:-,FCE:-,LCE:-] on CO
  • LockRequest[node=PA,lock:CX,PSE:-,NSE:-,FCE:-,LCE:-] on CO

Operations must be incompatible

CheckExisting LockRequest[node=CO,lock:NR,PSE:-,NSE:ER,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:EX,FCE:-,LCE:-] on CO
On CO The next sibling edge lock ER is incompatible to the requested EX
Incompatible
CheckExisting LockRequest[node=CO,lock:NR,PSE:-,NSE:ER,FCE:-,LCE:-]
with
Requested LockRequest[node=NS,lock:-,PSE:EX,NSE:-,FCE:-,LCE:-] on CO
Compatible
CheckExisting LockRequest[node=CO,lock:NR,PSE:-,NSE:ER,FCE:-,LCE:-]
with
Requested LockRequest[node=PA,lock:CX,PSE:-,NSE:-,FCE:-,LCE:-] on CO
Requested lock IX on AC compatible to existing lock IR.
Requested lock CX on PA compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=NS,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:EX,FCE:-,LCE:-] on CO
Requested lock IR on AC compatible to existing lock IR.
Requested lock IR on PA compatible to existing lock IR.
Compatible
CheckExisting LockRequest[node=NS,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=NS,lock:-,PSE:EX,NSE:-,FCE:-,LCE:-] on CO
On NS the previous sibling edge lock ER is incompatible to the requested EX
Incompatible
CheckExisting LockRequest[node=NS,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=PA,lock:CX,PSE:-,NSE:-,FCE:-,LCE:-] on CO
Requested lock IX on AC compatible to existing lock IR.
Requested lock CX on PA compatible to existing lock IR.
Compatible
Test Case Ok