Test Case taDOM3/3-taDOM3-6-LC

taDOM3 Lock Requests of executed Operation getPrevSibling(contextNode) returns null value

The getPrevSibling operation returns null because the context node CO is the first child of parent node PA and no previous sibling node PS exists.

Behavior specified with base operations:

  • readCO
  • useCOPSE
  • usePAFCE
Read Set = CO PAFCE COPSE , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]
  • LockRequest[node=PA,lock:-,PSE:-,NSE:-,FCE:ER,LCE:-]

taDOM3 Lock Requests of checked Operation getFirstChild(contextElementNode) executed on node LC

The getFirstChild operation returns the first child FC of the context node CO.

Bahavior specified with base operations:

  • readCO
  • useCOFCE
  • readFC
  • useFCPSE

Read and write sets for execution on LC:

Read Set = LC DC LCFCE DCPSE , Write Set =
  • LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:ER,LCE:-] on LC
  • LockRequest[node=FC,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] on LC

Operations must be compatible

CheckExisting LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:ER,LCE:-] on LC
Requested lock IR on AC compatible to existing lock IR.
Requested lock IR on PA compatible to existing lock IR.
Requested lock IR on CO compatible to existing lock NR.
Compatible
CheckExisting LockRequest[node=CO,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-]
with
Requested LockRequest[node=FC,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] on LC
Requested lock IR on AC compatible to existing lock IR.
Requested lock IR on PA compatible to existing lock IR.
Requested lock IR on CO compatible to existing lock NR.
Compatible
CheckExisting LockRequest[node=PA,lock:-,PSE:-,NSE:-,FCE:ER,LCE:-]
with
Requested LockRequest[node=CO,lock:NR,PSE:-,NSE:-,FCE:ER,LCE:-] on LC
Compatible
CheckExisting LockRequest[node=PA,lock:-,PSE:-,NSE:-,FCE:ER,LCE:-]
with
Requested LockRequest[node=FC,lock:NR,PSE:ER,NSE:-,FCE:-,LCE:-] on LC
Compatible
Test Case Ok